For IT and security

What runs on the lab computer, and what it does

Arvon is a command-line tool that reads a lab’s own microscope images and outcome records and writes a report. It installs offline, makes no network connections and writes only to the folder you name. Research use only, not a medical device.

01Network

No network connections, and how that is tested

  • No telemetry, no licence server, no update checks and no downloads at run time. The segmentation model weights ship with the software.
  • An automated test blocks all network access during a full pilot run, and the run still completes.
  • Every offline package is installed in our continuous integration with Python’s network access blocked, and must pass a pilot on synthetic data before it is released.
  • With Docker you can enforce it yourself with --network none.

Data never leaves the computer. Outputs are written only to the folder you name.

02Install

What gets installed

  • Offline package (Windows or Linux). A folder you copy to the lab computer by USB drive or internal share. Inside it, a Python 3.11 virtual environment is created and filled only from the copied files: pip runs with --no-index, so it never contacts the internet. The folder also holds the segmentation models (each pinned by SHA-256), the image processing recipes and the templates, so it stays where it was installed.
  • Or a Docker image, loaded from a file with docker load. It runs as a non-root user.
  • Checksums. Each download comes with a SHA256SUMS.txt file. Check it before unzipping.
  • Permissions. No administrator rights are needed once Python 3.11 is installed. It runs as an ordinary user.

To check the install, organoid-qc --version. To run a pilot, organoid-qc pilot followed by the data folder. It lists anything missing before it starts.

03Requirements

System requirements

Windows 10 or 11, or Linux (x86-64). Python 3.11. Four CPU cores. No GPU. Disk: about 1.5 GB for the software, plus about twice the size of the images being analysed.

The number of worker processes is chosen from the free memory at start-up and logged, so a smaller machine runs slower but does not run out of memory. It can be fixed with --workers N.

Recommended RAM for one image per well per timepoint, 12 timepoints.
PlateImage sizeRecommended RAMBasis
96-well1024 × 10248 GB (16 GB comfortable)Measured: 4.2 GB peak with 8 workers, 9.6 minutes
96-well2048 × 204816 GBEstimate, about 11 GB with 8 workers
384-well1024 × 102416 GBEstimate, about 8 GB with 8 workers
384-well2048 × 204832 GB (16 GB works with about 3 workers, slower)Estimate, about 18 GB with 8 workers

Estimates come from the measured memory per worker (about 0.45 GB, plus 0.1 GB per extra megapixel). The 384-well and 4-megapixel rows were not measured.

04Data

How it treats the lab’s files

  • Read only. Input images are hashed before and after processing, and a run stops if an input changes.
  • One output folder. Everything it writes goes to the output folder inside the data folder.
  • No identifying information. Intake refuses data that seems to contain names, dates of birth, record numbers or contact details, in metadata, file names or text embedded in images.
  • Codes, not names. Logs and reports name a lab only by a random code, never by lab or dataset name, and never contain images or file contents.
  • Encryption at rest, if wanted. AES-256-GCM, with a key file kept apart from the data.
  • Deletion with a receipt. Deletion first lists what it would remove. Once confirmed, it removes everything registered to a lab and writes a receipt with each file’s name, size and SHA-256 fingerprint.

Full detail: how your data is handled. Questions from IT or security teams: shreyan@arvon.bio.